Skip to main content

You must be a logged-in member of UHMS or a subscriber to the UHMS Journal in order to download the articles listed within these pages. If you are a member or subscriber, please log in using the Log In button above. If you would like to purchase a membership or a subscription, use the buttons below.

Search UHM/UBR

Whole-body active heating does not preserve finger temperature or manual dexterity during cold-water immersion

Background: Cold-water immersion impairs manual dexterity when finger temperature is below 15˚C. This exposes divers to increased risk of error. We hypothesized that whole-body active heating would maintain finger temperatures and dexterity during cold-water immersion. 

Methods: Twelve subjects (six males) (22±2 years old; BMI 23.9±2.5; body fat 16±6%) completed 60-minute head-out water immersion (HOWI) wearing a 7mm wetsuit and 3mm gloves in thermoneutral water (TN 25˚C) and cold water (CW 10˚C)while wearing a water-perfused suit (WP) with 37˚C water circulated over the torso, arms, and legs. Gross (Minnesota Manual Dexterity Test [MMDT]) and fine (modified Purdue Pegboard [PPT]) dexterity were assessed before, during and after immersion. Core body and skin temperatures were recorded every 10 minutes.

Results: MMDT (TN -25±14%; CW -72±23%; WP -67±29%; p<0.05) and PPT (TN -16±9%; CW: -45±10%; WP: -38±13%; p<0.05) performance decreased during immersion. MMDT and PPT did not differ between CW and WP. Immediately following immersion gross dexterity was recovered in all conditions. Post-immersion fine dexterity was still impaired in CW (p<0.01), but not WP or TN. Core and skin temperatures decreased during immersion in CW and WP (p<0.05) but did not differ between CW and WP.

Conclusions: Manual dexterity decreased during immersion. Dexterity was further impaired during cold-water immersion and was not maintained by water perfusion active heating. Warm water perfusion did not maintain finger temperature above 15˚C but hand temperature remained above these limits, suggesting a need to reassess thermal thresholds for working divers in cold-water conditions.

DOI: 10.22462/04.06.2020.11